Any plumbers in Da Haus?

What non motorbike related things are you doing, making, building, planning or designing
User avatar
mangocrazy
Posts: 6892
Joined: Tue Dec 22, 2020 9:58 pm
Has thanked: 2402 times
Been thanked: 3625 times

Any plumbers in Da Haus?

Post by mangocrazy »

In France I have a woodburning stove with back boiler that I'm in the process of fitting and doing pipework for. The stove will heat hot water in the cylinder and run up to 5 radiators. The dealer insisted that all pipework should be 28mm up to the cylinder/rads, but the inlet tappings on the DHW cylinder are only a paltry 14mm, so I have to reduce from 28mm to 14mm. I was thinking of going 28 => 22 => 18 => 14 but was wondering whether its' best to stagger the reductions over a few metres, or just bang them in one after the other in rapid sequence.

Does it make any difference or am I worrying about nothing?
There is no cloud, just somebody else's computer.
User avatar
Count Steer
Posts: 11804
Joined: Mon Jul 19, 2021 4:59 pm
Has thanked: 6375 times
Been thanked: 4750 times

Re: Any plumbers in Da Haus?

Post by Count Steer »

<wet finger in air>I'd guess that the shorter the length of smaller bore pipe, the better in terms of lower system pressure</wfia>
Doubt is not a pleasant condition.
But certainty is an absurd one
.
Voltaire
User avatar
mangocrazy
Posts: 6892
Joined: Tue Dec 22, 2020 9:58 pm
Has thanked: 2402 times
Been thanked: 3625 times

Re: Any plumbers in Da Haus?

Post by mangocrazy »

Yes, good point. The only thing I was thinking of is that a bore reduction will result in turbulence in the flow. Is it best to get it all out of the way quickly, or allow the flow to settle down between reduction points?
There is no cloud, just somebody else's computer.
User avatar
Count Steer
Posts: 11804
Joined: Mon Jul 19, 2021 4:59 pm
Has thanked: 6375 times
Been thanked: 4750 times

Re: Any plumbers in Da Haus?

Post by Count Steer »

mangocrazy wrote: Tue Sep 27, 2022 8:13 pm Yes, good point. The only thing I was thinking of is that a bore reduction will result in turbulence in the flow. Is it best to get it all out of the way quickly, or allow the flow to settle down between reduction points?
Looking at a towel rail here they have stepped down in 2 steps in the last few inches before the rail. It's a bit of an eyesore tbh. If you can get a 28-14mm coupling I'd go with that I think. Fewer possibilities for leaks, neater. If there are problems you can revert to plan B more easily than going the other way.

Disclaimer: Not a plumber. :D
Doubt is not a pleasant condition.
But certainty is an absurd one
.
Voltaire
Mussels
Posts: 4438
Joined: Mon Mar 16, 2020 9:02 pm
Has thanked: 836 times
Been thanked: 1238 times

Re: Any plumbers in Da Haus?

Post by Mussels »

If you struggle to find the right adapter then the answer may be to drill out a 28mm cap and solder some 14mm pipe to it.
I realise it's France but 14mm sounds odd, could it be 15mm?
User avatar
MingtheMerciless
Posts: 3552
Joined: Wed Mar 18, 2020 7:42 am
Location: Scarfolk on Sea
Has thanked: 2940 times
Been thanked: 1882 times

Re: Any plumbers in Da Haus?

Post by MingtheMerciless »

Just googled, they use 14mm copper pipe, amongst others.
"Of all the stories you told me, which ones were true and which ones weren't?"
"My dear Doctor, they're all true."
"Even the lies?"
"Especially the lies."
User avatar
mangocrazy
Posts: 6892
Joined: Tue Dec 22, 2020 9:58 pm
Has thanked: 2402 times
Been thanked: 3625 times

Re: Any plumbers in Da Haus?

Post by mangocrazy »

Plumbing sizes in France are different to the UK (unsurprisingly). 22mm copper is about the biggest you see here, then 18mm is the next size down, then 16, 14, 12, 10 and even 8! Wall thickness is 1mm. so 14mm copper will fit inside 16mm copper and you don't need an adapter. I've either got or can get all the step down sizes I need, but it's just whether to do a 'fast reduce' or a slow one.

Price of copper tube over here seems to be much more expensive than the UK, so I've brought stocks of 28, 22 and 15mm copper and fittings. If I use a swaging tool on 15mm copper I can get 14mm French copper to fit inside, so I can mix and match UK and French pipe.
There is no cloud, just somebody else's computer.
Silly Car
Posts: 854
Joined: Mon Mar 16, 2020 7:53 pm
Has thanked: 143 times
Been thanked: 497 times

Re: Any plumbers in Da Haus?

Post by Silly Car »

One of the reasons UK copper pipe may be cheaper, other than the tanking pound, is British Standard pipe is 0.7mm walled so 30% less material. Interestingly though (or not), 1mm walled copper pipe bends with far less likelihood of wrinkling than BS pipe.*


* I boringly watch a YouTube clip about it the other evening.
User avatar
MrLongbeard
Posts: 4580
Joined: Sun Mar 15, 2020 2:06 pm
Has thanked: 599 times
Been thanked: 2428 times

Re: Any plumbers in Da Haus?

Post by MrLongbeard »

Silly Car wrote: Tue Sep 27, 2022 9:44 pm * I boringly watch a YouTube clip about it the other evening.
And people tell me I need to get out more :crazy:

Although I watched vids about bear guns and treadmill cranes yesterday :think:
Bowman
Posts: 125
Joined: Sun Jun 05, 2022 2:46 pm
Has thanked: 161 times
Been thanked: 108 times

Re: Any plumbers in Da Haus?

Post by Bowman »

mangocrazy wrote: Tue Sep 27, 2022 6:38 pm In France I have a woodburning stove with back boiler that I'm in the process of fitting and doing pipework for. The stove will heat hot water in the cylinder and run up to 5 radiators. The dealer insisted that all pipework should be 28mm up to the cylinder/rads, but the inlet tappings on the DHW cylinder are only a paltry 14mm, so I have to reduce from 28mm to 14mm. I was thinking of going 28 => 22 => 18 => 14 but was wondering whether its' best to stagger the reductions over a few metres, or just bang them in one after the other in rapid sequence.

Does it make any difference or am I worrying about nothing?
The tappings into the cylinder sound extremely small. Is it an indirect cylinder? Are the flow and return gravity or pumped?
I'm not up on French plumbing but something doesn't seem quite right with that setup.
Kneerly Down
Posts: 719
Joined: Wed Apr 22, 2020 11:30 am
Has thanked: 164 times
Been thanked: 308 times

Re: Any plumbers in Da Haus?

Post by Kneerly Down »

Presume the 28mm is needed if it's not pumped. If you put a pump in the circuit I would have thought you could go with the smaller bore pipe. My inlaws used microbore for their central heating circuit for a big old 7 bed house and seemed to work well.
demographic
Posts: 3028
Joined: Mon Mar 16, 2020 9:30 pm
Location: Less that 50 miles away from Moscow, but which one?
Has thanked: 1346 times
Been thanked: 1722 times

Re: Any plumbers in Da Haus?

Post by demographic »

From memory I heard that its recommended to use large diameter pipes from backboilers to the hot water tank because below a certain diameter the thermosyphon doesnt really...erm...thermosyphon so well and you can boil the water in the backboiler.

Dunno what sizes they are but I guess it all depends on lengths of run and a number of other factors.
Might give you something to use as search criteria though.
User avatar
mangocrazy
Posts: 6892
Joined: Tue Dec 22, 2020 9:58 pm
Has thanked: 2402 times
Been thanked: 3625 times

Re: Any plumbers in Da Haus?

Post by mangocrazy »

Well, it's done now and I'm back home in Blighty. I used 28mm up until about half a metre away from the cylinder when I stepped down to 15mm , as it was easier to make the routing in small diameter pipe (the cylinder is quite close to a wall and there's no direct line of sight to the take-offs). Then I stepped down from 15mm to 14mm at the cylinder.

In an ideal world I'd have taken the 14mm fitting on the cylinder off and found a 22mm tapping underneath, but when I tried to undo the 14mm tapping on the cylinder it didn't budge even after some fairly heavy persuasion, so I bottled it and left it at 14mm, and the associated steps down. Here's a pic of how I left it:

Cylinder_plumbing.jpg
Cylinder_plumbing.jpg (310.09 KiB) Viewed 121 times

And this is a section I added while I was there:

Copper_spaghetti.jpg
Copper_spaghetti.jpg (409.96 KiB) Viewed 121 times
There is no cloud, just somebody else's computer.