Tmax xp500 charging fault
- Taipan
- Posts: 13948
- Joined: Sat Mar 14, 2020 1:48 pm
- Location: Essex Riviera!
- Has thanked: 15955 times
- Been thanked: 10248 times
Tmax xp500 charging fault
The Tmax isn't charging. They are not exactly unknown for burning out reg/rectifiers. I got a supposedly good s/hand reg and chucked it on today but it hasn't cured it. So i decided to start taking some readings on both regulators off the bike and it looks like s/hand one is faulty but the one that is on there is within spec? Can anyone check my work and confirm this?
OEM Reg. Using a DMM.
Positive probe to regulator negative connector and the reading from each of the 3 phase connectors.
con1 511 - con2 500 - con3 520
Negative probe to regulator positive connector
con1 521 - con2 520 - con3 525
S/hand Reg. Using a DMM.
Positive probe to regulator negative connector and the reading from each of the 3 phase connectors.
con1 519 - con2 1 - con3 522
Negative probe to regulator positive connector
con1 532 - con2 533 - con3 520
I'm thinking second hand one has faulty diode and no good, but the OEM one is within spec, or are those figures too far apart?
Moving on to checking the stator, iirc, any continuity between any of the 3 phase wires and earth means it's had it?
OEM Reg. Using a DMM.
Positive probe to regulator negative connector and the reading from each of the 3 phase connectors.
con1 511 - con2 500 - con3 520
Negative probe to regulator positive connector
con1 521 - con2 520 - con3 525
S/hand Reg. Using a DMM.
Positive probe to regulator negative connector and the reading from each of the 3 phase connectors.
con1 519 - con2 1 - con3 522
Negative probe to regulator positive connector
con1 532 - con2 533 - con3 520
I'm thinking second hand one has faulty diode and no good, but the OEM one is within spec, or are those figures too far apart?
Moving on to checking the stator, iirc, any continuity between any of the 3 phase wires and earth means it's had it?
- DefTrap
- Posts: 4495
- Joined: Tue Apr 14, 2020 8:23 am
- Has thanked: 2260 times
- Been thanked: 2191 times
Re: Tmax xp500 charging fault
That electrex fault finding guide - always a winner https://www.electrosport.com/pages/technical-resources
"When you find that there is a problem, keep in mind that the number 1 problem with any charging system are bad connections."
And battery, obvs.
I only mention it because of the numerous crappy bikes with crappy electrics I've had over the decades, it's ALWAYS been one of those two.
"When you find that there is a problem, keep in mind that the number 1 problem with any charging system are bad connections."
And battery, obvs.
I only mention it because of the numerous crappy bikes with crappy electrics I've had over the decades, it's ALWAYS been one of those two.
- wull
- Posts: 3065
- Joined: Sun Aug 15, 2021 6:09 pm
- Location: Alloa
- Has thanked: 880 times
- Been thanked: 1544 times
Re: Tmax xp500 charging fault
Check output from the alternator.
Best way to test it is the actual voltage output which is AC with the meter range set to at least 500
All you have to do is test each wire, so one probe on one pin and the other probe on the other pin until you have taken the 3 readings, all 3 should be within spec so check the manual, usually done with the bike revving @ 4K but can vary.
Best way to test it is the actual voltage output which is AC with the meter range set to at least 500
All you have to do is test each wire, so one probe on one pin and the other probe on the other pin until you have taken the 3 readings, all 3 should be within spec so check the manual, usually done with the bike revving @ 4K but can vary.
-
- Posts: 13938
- Joined: Mon Mar 16, 2020 7:57 pm
- Location: Milton Keynes
- Has thanked: 2551 times
- Been thanked: 6245 times
Re: Tmax xp500 charging fault
BTW....I've been caught out before by a digital multi meter with a dying battery. They generate pseudo random readings, so if you're scratching your head at the weird numbers you're getting try changing the battery in the meter
- Taipan
- Posts: 13948
- Joined: Sat Mar 14, 2020 1:48 pm
- Location: Essex Riviera!
- Has thanked: 15955 times
- Been thanked: 10248 times
Re: Tmax xp500 charging fault
Got an interesting reply from a knowledgeable chap. Seems it may be my regulator after all? One is winging its way to me as we speak and I'll do that 10-minute job as part of the elimination process. I also have a stator winging its way to me in case it isn't the reg. That is obviously a much more involved job though, so fingers crossed on the reg being at fault!
"The GAP of testing between NEG and POS should not have that much GAP. and it should be Very CLOSE to each other. Is your bike a yamaha TMAX 500? reading is quite high as per my example...
Here's your gap 511/521 - 500/520 - 520/525
as you can see the new rectifier gap is 464/463 - 463/464 - 471/471
Damage rectifier - 469/466 - 466/469 - 470/475"
"The GAP of testing between NEG and POS should not have that much GAP. and it should be Very CLOSE to each other. Is your bike a yamaha TMAX 500? reading is quite high as per my example...
Here's your gap 511/521 - 500/520 - 520/525
as you can see the new rectifier gap is 464/463 - 463/464 - 471/471
Damage rectifier - 469/466 - 466/469 - 470/475"
-
- Posts: 582
- Joined: Thu Jun 18, 2020 10:41 pm
- Has thanked: 479 times
- Been thanked: 310 times
Re: Tmax xp500 charging fault
I know nothing about any of that, but I do remember my TMax 500 ate batteries at a pretty alarming rate - about one every two years. Whether that's connected to the issues you are talking about I don't know?
- Taipan
- Posts: 13948
- Joined: Sat Mar 14, 2020 1:48 pm
- Location: Essex Riviera!
- Has thanked: 15955 times
- Been thanked: 10248 times
Re: Tmax xp500 charging fault
There are no charging volts going in. I think it's the stator and I have a new one but was waiting on Hermes to deliver the new regulator on Thursday or Friday last week. It turned up at 18:15 last night! The regulator is a 10-minute job to change but the stator is a lot more involved, hence why I wanted to check the new reg first.
- wull
- Posts: 3065
- Joined: Sun Aug 15, 2021 6:09 pm
- Location: Alloa
- Has thanked: 880 times
- Been thanked: 1544 times
- Taipan
- Posts: 13948
- Joined: Sat Mar 14, 2020 1:48 pm
- Location: Essex Riviera!
- Has thanked: 15955 times
- Been thanked: 10248 times
Re: Tmax xp500 charging fault
Yes i will do. DMM needed a battery and then I buried the bike under a cover and had some old cupboards I was cutting up in front of it. I'm pretty sure the stator has gone as before my meter battery croaked, I'm sure I got continuity to earth (I think) on one of the circuits? Anyway, the bike does run so I can test static and dynamic as well.
- wull
- Posts: 3065
- Joined: Sun Aug 15, 2021 6:09 pm
- Location: Alloa
- Has thanked: 880 times
- Been thanked: 1544 times
Re: Tmax xp500 charging fault
Yeah test the voltage output of the stator windings as well, I always find this will give you better results.
- Taipan
- Posts: 13948
- Joined: Sat Mar 14, 2020 1:48 pm
- Location: Essex Riviera!
- Has thanked: 15955 times
- Been thanked: 10248 times
Re: Tmax xp500 charging fault
Meter on AC volts with the bike running and probes across each of the three wires, 2 at a time right?
-
- Posts: 2527
- Joined: Mon Mar 16, 2020 7:37 pm
- Location: Layer-de-la-Haye
- Has thanked: 2248 times
- Been thanked: 1242 times
- wull
- Posts: 3065
- Joined: Sun Aug 15, 2021 6:09 pm
- Location: Alloa
- Has thanked: 880 times
- Been thanked: 1544 times
Re: Tmax xp500 charging fault
As above, try and find out what the manual says with regards to the output, it’ll probably be something like 40-50v @4k so make sure the meter is set to a minimum range of 50v AC.
- Taipan
- Posts: 13948
- Joined: Sat Mar 14, 2020 1:48 pm
- Location: Essex Riviera!
- Has thanked: 15955 times
- Been thanked: 10248 times
Re: Tmax xp500 charging fault
Manual says,
AC volts readings
1&2 idle 25 5k 74
1&3 idle 20 5k 74
3&2 idle 21 5k 73
OHMs
1&2 0.5
1&3 0.5
3&2 0.5
Resistance across the probes 0.3 So I'm about in spec, right? But all the wires sound the continuity bleeper when connecting any of the 3 wires to earth. So the stator is shot? Thoughts?
TIA
AC volts readings
1&2 idle 25 5k 74
1&3 idle 20 5k 74
3&2 idle 21 5k 73
OHMs
1&2 0.5
1&3 0.5
3&2 0.5
Resistance across the probes 0.3 So I'm about in spec, right? But all the wires sound the continuity bleeper when connecting any of the 3 wires to earth. So the stator is shot? Thoughts?
TIA
-
- Posts: 2527
- Joined: Mon Mar 16, 2020 7:37 pm
- Location: Layer-de-la-Haye
- Has thanked: 2248 times
- Been thanked: 1242 times
Re: Tmax xp500 charging fault
If you have continuity to earth then its fit for the bin, what is the actual resistance between phases and to earth?
- Taipan
- Posts: 13948
- Joined: Sat Mar 14, 2020 1:48 pm
- Location: Essex Riviera!
- Has thanked: 15955 times
- Been thanked: 10248 times
Re: Tmax xp500 charging fault
2.4 on all 3 phases.v8-powered wrote: ↑Fri Oct 15, 2021 12:46 pm If you have continuity to earth then its fit for the bin, what is the actual resistance between phases and to earth?
-
- Posts: 2527
- Joined: Mon Mar 16, 2020 7:37 pm
- Location: Layer-de-la-Haye
- Has thanked: 2248 times
- Been thanked: 1242 times
Re: Tmax xp500 charging fault
2.4 Ohms to earth? That sounds like it's farked then.....Taipan wrote: ↑Fri Oct 15, 2021 2:15 pm2.4 on all 3 phases.v8-powered wrote: ↑Fri Oct 15, 2021 12:46 pm If you have continuity to earth then its fit for the bin, what is the actual resistance between phases and to earth?
- Taipan
- Posts: 13948
- Joined: Sat Mar 14, 2020 1:48 pm
- Location: Essex Riviera!
- Has thanked: 15955 times
- Been thanked: 10248 times
Re: Tmax xp500 charging fault
Thanks. On it, like a car bonnet!v8-powered wrote: ↑Fri Oct 15, 2021 3:24 pm2.4 Ohms to earth? That sounds like it's farked then.....Taipan wrote: ↑Fri Oct 15, 2021 2:15 pm2.4 on all 3 phases.v8-powered wrote: ↑Fri Oct 15, 2021 12:46 pm If you have continuity to earth then its fit for the bin, what is the actual resistance between phases and to earth?
- weeksy
- Site Admin
- Posts: 23421
- Joined: Sat Mar 14, 2020 12:08 pm
- Has thanked: 5451 times
- Been thanked: 13087 times
Re: Tmax xp500 charging fault
Oh you can get a high resolution pic.
I really wish that wasn't possible
I really wish that wasn't possible